Asenware 2 Zone Fire Alarm Panel AW-CFP2166-2

Availability:In Stock!


Asenware 2 Zone Fire Alarm Panel AW-CFP2166-2

1. AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2. It is modularized design, the panel can expand from 1 zone to 32 zones easily.
3. It has 2 level control mode by a lock.
4. It has 24VDC power supply output.
5. It has FIRE and FAULT signal output.
6. It has 2 general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.

KSh 13,500.00

Compare

Asenware 2 Zone Fire Alarm Panel AW-CFP2166-2

The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.

Product Features

1. AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2. It is modularized design, the panel can expand from 1 zone to 32 zones easily.
3. It has 2 level control mode by a lock.
4. It has 24VDC power supply output.
5. It has FIRE and FAULT signal output.
6. It has 2 general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. It has SILENCE button to stop BUZZER and SOUNDERS.
11. It has EVACUATE button to start a manual fire alarm immediately.
12. It has an optional GSM module for fire alarm by SMS.
13. It is economic, user-friendly and easy maintenance.

 

Mains supply voltage 110VAC or 220VAC
Internal power supply 27.2VDC
Total output current limited 500mA @ 240VAC
Batteries (default configuration) 12V2.3AH*2
Number of circuit 2
End of Line device 6.8k Ω,5% tolerance, 0.5-1W (colour code-blue,grey,red,gold)
Call point resistor value 470 to 680 Ω, 0.5 or 1 watt
Number of general circuits 2
Outputs fused AT 600mA
Maximum number of bells @ 50mA of each Sounder output 12
Battery fuse 1.85A resettable fuse
Sounder outputs 400mA F 20mm
Output type NC and NO relay
Maximum current 100mA
Largest acceptable conductor size 2.5mm2
Smallest acceptable conductor size 0.75mm2
Dimensions(mm) 320X231X90
Weight (with batteries) 7kg